Rio Fuse Specifications Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
GFCI
ONLY
Drip Loop
Controller
UL Listed
Transformer
Mini Sun Moon Light
(Optional part)
1 1
7
8
9
10
11 12 13 14
15
16
3 6
4
5
2
YES
NO
8
9
10
11 12
13
the screen will now read 15 and the blue/second LED will be lit. If set on the LEFT or
RIGHT setting, the screen, will not be lit and pump will run continually.
13. Press the SET button until the desired time parameter is set. (a) Blue LED is
seconds. (b) Yellow LED is minutes
14. Once the desired time is set. Press the ENTER button.
15. To change time, press the SET button to desired set time and then press the ENTER
button.
16. When feeding, press the desired feeding time 8 or 16 minutes.
Note: Polario™ pumps are equipped with an automatic safety SHUT-OFF.
If the pump is on and is removed from water, it will automatically shut off. To reset, secure the pump
back on the magnet mount, then turn controller OFF then ON to reset.
MAINTENANCE:
It is the utmost importance to clean and maintain the pump monthly. Remove the Large intake strainers
and the endcaps to access the propeller. Remove the propeller which should slide off the motor easily.
Now reinstall and verify that the propeller rotates easily around the motor. If the propeller binds or there
is too much drag created: the motor, propeller and ceramic shaft need to be cleaned well. These high
speed motors attract calcium build up, let the pump soak in a water/vinegar solution for a minimum of
1 hour. (3 parts water to 1 part vinegar) Then clean well with a small brush. If the pump has not been
maintained on a regular basis or if high amount of calcium is added this process may be needed to be
repeated. If there is any noticeable damage to the propeller replace immediately.
Verify the intake strainers are free and clean of all debris
TROUBLE SHOOTING
Controller will not power up and/or pump will not turn on: It is imperative to keep the pump clean and well
maintained to ensure the pump is in good working order and the impeller and strainer clean at all times,
failure to do so will cause the 15 ML & 22 ML controller to shut down until the problem or problems are
rectified. At that time the unit may just go to default setting where as the controller is plugged in and the
green transformer light will be on however the controller will not power up or may power up for just a
few seconds then shut down. In some instances the controllers fuse has blown in addition to going to
default setting. Replace fuse with a 22ML 3.5a/250v and 15ML 3.5a/250v slow blow fuse.
SOLUTION:
1. Check all intake strainers verifying that they are free of all debris.
2. Remove the Large intake strainers and the endcaps to access the propeller. Verify that there is not
anything blocking the propellers rotation.
3. Remove the Large intake strainers and the endcaps to access the propeller. Remove the propeller
it should slide off the motor easily. Now reinstall and verify that the propeller rotates easily around
the motor. If the propeller binds or there is too much drag created: the motor, propeller and ceramic
shaft need to be cleaned well. These high speed motors attract calcium build up, let the pump soak
in a water/vinegar solution for a minimum of 1 hour. (3 parts water to 1 part vinegar) Then clean
well with a small brush. If the pump has not been maintained on a regular basis or if high amount of
calcium is added this process may be needed to be repeated. If there is any noticeable damage to
the propeller replace.
15ML & 22ML
FEATURE
TURBINE DUAL ACTION
PROGRAMMABLE AQUA PUMP
• Energy efficient, high flow low voltage water pump
• Bi-directional outputs to simulate natural wave and
current actions of the ocean
• Variable time and output settings
• Flow rates up to 5,500GPH/22,000LPH
(on selected models)
• Single or dual outputs
• Preset feeding settings at 8 and 16 min.
• Magnet mount Included to secure pump
• Pre-programmed in all settings to gradually
Increase flow
• In “Auto” mode, pump initially alternates 15 sec.,
left and right
• The alternating water currents can be set to switch
every 15 sec. to 30 min.
• Mini sun moon light adapter included
• 16 volt UL listed transformer included
PART LIST
1. Couplers
2. Propeller
3. Large strainers
4. Main pump housing
5. Endcaps
6. Water diverters
7. Controller
8. Magnet Mount
9. Pump extension
10. O-Ring
11. Power supply connection
12. Pump connection
13. Fuse
14. Mini sun moon light adapter
15. UL listed transformer
16. Transformer power
supply cord
REPLACEMENT PARTS
Part Number Description
2 Polario
TM
15ML Propeller
2 Polario
TM
22ML Propeller
8 Polario
TM
15ML MM300 Magnet Mount
8 Polario
TM
22ML MM500 Magnet Mount
10 Polario
TM
O-Ring
15 Polario
TM
15ML UL Listed Transformer
15 Polario
TM
22ML UL Listed Transformer
DIRECTIONS FOR INSTALLING
1. Select the mode on the controller in which the pump will
operate. There are three options: (a) “Auto” or alternating
discharge from left to right. (b) Left. (c) Right.
2. Choose a location for the pump.
3. Attach pump extension to the pump.
4. Install magnet mount: (a) Read all warnings! Handle this
product with care, failure to do so will cause injury and/or
damage to your aquarium. (b) Remove from box.
(c) Choose the desired placement for the magnetic
holder. (d) Separate the magnet holders by twisting units
apart. (e) Place the magnet in the desired location in the
aquarium.The magnet must be flat on the glass.
f. Place the outer magnet flat on the glass and slide it to
the inner magnet until they engage.
5. Attach the pump to the magnet mount.
6. Mount and secure the controller above and away from the
aquarium in an area that is dry and will stay dry.
7. Mount and secure the transformer in an area that is dry
and that will stay dry.
8. Plug the transformer into the controller.
9. Plug the pump into the controller.
10. Set the flow rate. It is recommended to set the flow at low
flow rate then adjust accordingly.
11. While the unit is OFF, plug the transformer into a GFCI
electrical receptacle.
12. Turn the controller ON. If the controller is set on AUTO
SPECIFICATIONS
Item # Watt
Pump Size
L x Dia. (Approx.)
Flow Rate (Approx.)
Aquarium Size
(Approx.)
Output O.D. Transformer Fuse Glass Thickness
UPC #
0006760
LPH GPH
4ML 7w
1.9 x 2 in
(4.8 x 5 cm)
2300-4000 600-1000
10-20 Gal.
(35-80 Ltr.)
2 in (50 mm)
9v
1.6 amp
fast blow fuse
0.27 in
(7 mm)
1024 2
7ML 23w
2.1 x 2.4 in
(5.4 x 6 cm)
5000-7000 1300-1800
30-50 Gal.
(115-190 Ltr.)
2.4 in (60 mm)
2.5 amp
fast blow fuse
0.7 in
(18 mm)
1025 9
10ML 25w 6000-10000 1500-2600
40-100 Gal.
(150-380 Ltr.)
1026 6
15ML 30w
9.5 x 3in
(24 x 7.7 cm)
12000-15000 3000-3500
50-150 Gal.
(190-570 Ltr.)
2.55 in (65 mm) 16v
3.5 amp
slow blow fuse
0.5 in
(12 mm)
1015 0
22ML 50w 18000-22000 4500-5500
90-250 Gal.
(340-950 Ltr.)
3.5 amp
slow blow fuse
0.75 in
(20 mm)
1016 7
LIMITED WARRANTY
T.A.A.M. Inc.
®
warrants that the Polario™ is free from defects for a period of six months from the initial date
of purchase shown on the original cash register receipt. T.A.A.M. Inc.
®
disclaims all other warranties of merchantability
and/or fitness for a particular purpose. Although this limited warranty may give you specific rights, you may have other
rights that may vary from state to state. This warranty is void if the failure of the controller or any part, sealant or
component there of is due to (i) misuse, (ii) tampering, (iii) negligence, (iv) misapplication, (v) abuse, (vi) accident and/
or (vii) failure to properly (a) maintain, (b) clean, (c) keep free from water and moisture and/or use the controller with a
Ground Fault Circuit Interrupter (GFCI).
CONSUMER REMEDIES
T.A.A.M. Inc.
®
’s entire liability and your sole and exclusive remedy shall be either repair or replacement
of the Polario™ only if you return the defective unit directly to T.A.A.M. Inc.
®
with the original receipt in its original box
along with twenty dollars ($20.00) for shipping and handling. Do not send Polarioby insured mail. You may send
your returns or replacements by UPS if requiring a signature upon arrival. Any replaced unit will be warranted for the
remaining time of the original warranty period. In no event shall any shipping charges be reimbursed. In no event will
T.A.A.M. Inc.
®
be liable for any consequential or incidental damages, including but not limited to, lost sea life, personal
injury, property damage, equipment damage, lost profits, lost wages, lost savings, lost income, etc., arising out of the
use of the Polario™. Some states do not allow for the limitation or exclusion of liability for incidental or consequential
damages, so the above exclusion may not apply to you.
RETURNS
Please contact our service center at (805) 383-3566 ext. 102 or fax (805) 383-3565 to arrange repair and/
or replacement. Please allow 4-6 weeks for all returns.
WARRANTY CARD
Please go to our website, to download Warranty Card.
http://www.riopump.net/Resources_folder/Warranty.html
Fill out this warranty card and mail it with PROOF OF PURCHASE
within 15 days of purchase
Page view 1
1 2